STERILIZATION TEST HELIX TEST conf. 50 strips
STERILIZATION TEST HELIX TEST conf. 50 strips
STERILIZATION TEST HELIX TEST conf. 50 strips
STERILIZATION TEST HELIX TEST conf. 50 strips

STERILIZATION TEST HELIX TEST conf. 50 strips

EM14075
Available
$54.97
Tax excluded

STERILIZATION TEST HELIX TEST conf. 50 strips

Helix test is a physical test to check the capacity of the steam penetration of hollow bodies. For testing, a standardized system is used and comply with the technical regulations currently in force. The test must be passed by all the autoclaves which declare the possibility of sterilization of hollow bodies such as handpieces, turbines, pipes etc ...

FEATURES: • Support non-toxic paper weighing 170 g / m2. One side of the support is provided with adhesive to allow the storage of the test. • Dimensions: 75 x 5 mm • non-toxic marker ink resistant to water and heat, applied with screen printing process (original color: blue). • The indicator ink does not contain lead or other heavy metals and is formed by 6 different com ponents can develop a specific chemical reaction of the third kinetic order. • The indicator is classified according to EN ISO 11140-1 as Class 2 (specific test indicator) and as a Class 6 (emulation indicator). • The indicator is sensitive to the sterilization parameters: time, temperature and saturated steam. • If the indicator is subjected to a proper sterilization cycle, the indicator ink changes from light blue to dark green (the reference color change is represented by the logo of the manufacturer and by the three inscriptions present on the strip). • The product is completely free of latex.

INSTRUCTIONS: 1. Open the HELIX cannula. 2. Fold the strip in the incision. The indicator ink can be facing either inwards or outwards {FIGS 1 and 2). 3. Place the strip so folded into the cannula capsule (Figure 3). 4. Richiuderela cannula HELIX (Figure 4). 5. Make a disterilizzazione cycle. The sterilization parameters necessary to obtain the color change of 'nchiostroindicatore are (Art. 13.00203 million): 134 ° C saturated steam for 3.5 minutes or 121 ° C saturated steam for 15 minutes. 6. When the aprirela capsule device testing and remove the indicator. 7. If the totaltà area present within the device has been effectively removed, the saturated steam has penetrated to 'nternal of the cannula up to the room and the temperature of 134 ° C was maintained for at least 3.5 minutes (alternatively: 121 ° C for 15 minutes} the indicator ink will be tacked from light blue to dark green to indication that tuttii of sterilzzazione parameters have been met (the reference color is represented by the inscriptions on the strip: text and logo) . 8. the indicator strip is provided with adhesive unlato to allow a practical permanent storage.

Product Details

Grade Comments (0)

No customer reviews for the moment.
Product added to wishlist
Product added to compare.